Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Modèle: SYS120VDC12000W
Lieu D'origine: Chine
Input Voltage: 190~265VAC
Input Frequency: 47~63Hz
Input Power Max: 15KW
Power Factor: ≥0.98
Output Voltage Range: 0~120V
Output Current Range: 0~120A
Output Power Range: 0~12000W
Height: 13U
Warranty: 2 years
Détails d'emballage: cartons
transport: Air
Hafen: DHL
Type de paiement: T/T
Incoterm: EXW
Achetez des alimentations programmables haute performance qui fournissent une alimentation de tension variable stable d'APM! Vous pouvez choisir le modèle approprié ici, quel que soit le niveau de tension dont vous avez besoin comme l'alimentation 15VDC ou l'alimentation 24VDC ou bien. De nombreux contrôles permettent un séquençage sophistiqué, un mode de courant constant, un mode de tension constante et une sauvegarde / rappel des configurations courantes. La qualité de l'énergie fournie par APM le rend bien adapté à une très large gamme d'applications .
Il existe plus de modèles, un système source CC 40V, un système source CC 75V, un système source CC 150V, un système source CC 200V, un système source CC 600V, un système source CC 800V pour votre référence.
Zone de candidature :
Cette série s'applique à plusieurs secteurs tels que les secteurs électriques, d'éclairage et d'aviation et pourrait également être appliqué au test de production de l'entreprise.
Caractéristiques du produit:
● avec une tension précise et une capacité de mesure du courant.
● Bouton codé, clavier multifonction.
● Les interfaces de communication RS232 / RS485 / USB standard, LAN et GPIB sont facultatives.
● Compensation de tension de la ligne de télédétection Compensation.
● Équipe de la fonction d'édition de forme d'onde de liste.
● Utilisez les commandes standard pour le protocole de communication d'instrumentation programmable (SCPI).
● ont obtenu la certification CE.
Spécifications techniques:
ltem | MODEL | SYS120VDC12000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 75A | |
5 | Input Power Max | 15kW | |
6 |
Power Factor at 220VAC Input ,Full Load |
0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~120V | |
9 | Output Current | 0~120A | |
10 | Output Power | 12kW Max | |
11 | Load Regulation | Voltage | 120mV |
12 | Current | 0.12A | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~120V |
16 | Resolution | 1mV | |
17 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
18 | Current Setting | Range | 0~120A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 160mVp-p/30mVrms |
22 | Current | 90mA(Full Range),15mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~120V |
24 | Resolution | 1mV | |
25 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc |
|
26 | Current Setting | Range | 0~120A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~360V | |
30 | Output Current | 0~40A | |
31 | Output Power | 12kW Max | |
32 | Load Regulation | Voltage | 120mV |
33 | Current | 0.12A | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~360V |
37 | Resolution | 10mV | |
38 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
39 | Current Setting | Range | 0~40A |
40 | Resolution | 0.1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 120mVp-p/22.5mVrms |
43 | Current | 120mA(Full Range),20mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~360V |
45 | Resolution | 10mV | |
46 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
47 | Current Setting | Range | 0~40A |
48 | Resolution | 0.1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232(Standard); LAN,GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*736.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*910.0*820.0 mm | |
67 | Unit Net Weight | 54kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 94kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
Groupes de Produits : Système source CC > Système source 120 V CC
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.